The importance of the test specification of pulse group generator
Release time: 2018-06-22Views: 1,091

The pulse group generator test uses interference to charge the line junction capacitance. When the energy on the junction capacitance accumulates to a certain extent, it may cause errors in the line (or even the system). Therefore, there is a process of line error, and there is a certain contingency. It cannot be guaranteed that the error will occur at any interval, especially when the test voltage is close to the critical value. For this reason, some product standards stipulate that the test on the power line is conducted between the line and the ground. It is required to conduct three tests on one line under one test voltage polarity, one minute each time, with an interval of one minute: after one polarity is completed, change to another polarity. When one line is finished, change to another line. Of course, pulses can also be injected into two lines, or even several lines at the same time. Because the transmission process of the pulse group generator signal on the power line is very complex, it is difficult to judge whether to add pulses separately or together, and the equipment is more likely to fail.

Therefore, adding pulses at the same time is only a form of experiment, and it is ultimately up to the experiment to draw a conclusion.

Other standards (such as gb4343.2) stipulate that 2min positive polarity pulse shall be added to one line first, and then 2min negative polarity pulse shall be added after a short rest. It can be seen that different standards have different provisions, but they all have a relatively long test process to avoid contingency. And expose hidden dangers through a variety of combinations. Usually, the test object is only sensitive to the test of one wire and one polarity.

Burst immunity test is a kind of test that is difficult to pass in all common immunity tests, and it is also a kind of test with poor repeatability and comparability. Therefore, in the description of this section, it is emphasized that the essence of this test is common mode test. Because the waveform contains rich harmonic components and high upper limit frequency, the standardization of the test is particularly important.

 

Share to
Return to list
九九色九九| 激情骚妇| 69久久久| 个人极品色综合| 亚洲熟妇av一区| 日本免费看A久久| 国产尤物无码一区二区三区| 成年人免费在线观看av| 风间性色精品一区二区中村知慧| 1024亚洲精品无码| 久久久久久熟女熟妇| 欧美日韩bv一区二区综合| 内射资源站| 日本天堂在线| 征服朋友极品人妻| 欧州aV免费久久一区二区三区 | 激情网站| 国产aa视频| 欧美 日本 少妇 中文字幕| 孕妇孕交孕| 国产swag无码在线| 午夜福利国产一级| 日本最新中文字幕久久| 东京热人妻无码一区二区av | 天堂v在线| 成人亚洲精品在线观看视频| 亚洲欧美日韩激情在线图片小说 | 日韩中文字幕国产| 日本道在线| 亚洲精品中文字幕日韩日本| 亚洲色图欧美五月婷婷| 边弄边进去动漫| 色六月天天激情综合网| 国产精品99久久久精品免费观看| 亚洲一区精品无码色成人| xxav| 国产成人亚洲欧美二区综合| 久久久中文久久久无码| 欧美日韩中文国产一区| 粉嫩小穴久久| 日本无遮挡边做边爱边摸亮点|